Transitions between different modes and types

F-mode to 1O-mode
F-mode to 1O-mode

Mode transition from the F-mode (I-type) to the 1O-mode (S2-type) for the radiative loss function adapted from Cook et al. Shown are the time evolution of the size of the leading shell (left) and the post shock temperature (right). (Taken from Walder and Folini, AA 315, 265, 1996, Fig.7.)
1O-mode to F-mode
1O-mode to F-mode

Mode transition from the 1O-mode (M-type) to the F-mode (C-type) at T_postshock < 5*10^5 K for the radiative loss function adapted from Schmutzler and Tscharnuter. Shown are the time evolution of the size of the leading shell (left) and the post shock temperature (right). (Taken from Walder and Folini, AA 315, 265, 1996, Fig.9.)
Send comments to:
Doris Folini and Rolf Walder